Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hand Surg Asian Pac Vol ; 29(1): 36-42, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38299239

RESUMO

Background: Despite the good clinical results in the treatment of Kienböck disease with distal radius core decompression, a radiological progression to a certain degree in the long-term follow-up is possible. Is there a negative correlation between the clinical improvement of the patients and the radiological progression? Methods: We retrospectively reviewed the radiological and clinical results of 24 patients (mean age: 38 years; 10 women) treated with core decompression for Kienböck disease. The mean follow-up was 10 years. Results: A radiologic progression in the Lichtman classification was seen in nine patients. The Spearman correlation did not show any correlation between this radiological progression and the clinical outcome. Namely -0.06 between Mayo and Lichtman classification and 0.16 between VAS and Lichtman classification. Conclusions: We found that the clinical outcomes do not deteriorate despite a radiological progression of patients treated with core decompression for Kienböck disease Level of Evidence: Level IV (Therapeutic).


Assuntos
Osteonecrose , Rádio (Anatomia) , Humanos , Feminino , Adulto , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Estudos Retrospectivos , Seguimentos , Osteotomia/métodos , Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Descompressão
2.
EFORT Open Rev ; 8(4): 162-174, 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37097047

RESUMO

Purpose: The biomechanical characteristics of different techniques to perform the modified Lapidus procedure are controversial, discussing the issue of stability, rigidity, and compression forces from a biomechanical point of view. The aim of this systematic review was to investigate the available options to identify whether there is a procedure providing superior biomechanical results. Methods: A comprehensive literature search was performed by screening PubMed, Embase, and Cochrane databases until September 2021. There was a wide heterogeneity of the available data in the different studies. Load to failure, stiffness, and compression forces were summarized and evaluated. Results: Seventeen biomechanical studies were retrieved - ten cadaveric and seven polyurethane foam (artificial bone) studies. Fixation methods ranged from the classic crossed screw approach (n = 5) to plates (dorsomedial and plantar) with or without compression screws (n = 11). Newer implants such as intramedullary stabilization screws (n = 1) and memory alloy staples (n = 2) were investigated. Conclusion: The two crossed screws construct is still a biomechanical option; however, according to this systematic review, there is strong evidence that a plate-screw construct provides superior stability especially in combination with a compression screw. There is also evidence about plate position and low evidence about compression screw position. Plantar plates seem to be advantageous from a biomechanical point of view, whereas compression screws could be better when positioned outside the plate. Overall, this review suggests the biomechanical advantages of using a combination of locking plates with a compression screw.

3.
Injury ; 52(8): 2292-2299, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34053774

RESUMO

BACKGROUND: Several surgical techniques of osteosynthesis have been described for treatment of proximal humeral fractures. There is evidence that the quality of reduction improves the clinical outcome and decreases the number of complications. Reduction of the medial calcar is tricky when standard manoeuvres are performed. We have therefore augmented our standard surgical technique with a low-profile medial hinge plate which aims at better reconstructing the medial metaphysis without extensile soft tissue dissection in combination with proximal humerus locked plating. OBJECTIVE: Evaluate the radiological and clinical outcome after application of an augmented fixation with a low-profile medial hinge plate. We questioned: (i) The quality of reduction, (ii) The rate of complications, (iii) The clinical function in terms of the Oxford Shoulder Score (OSS). METHODS: A retrospective single-centre case series. Between 2016 and 2019, patients who had undergone open reduction and osteosynthesis by an anatomical locking plate associated with a 2.0 mm locking compression plate used as a hinge to support the medial metaphysis. Thirty-four patients, with an average age of 64 years had a clinical and/or radiological average follow-up of 36 months. RESULTS: The preoperative imaging identified three fractures in two parts, 19 fractures in three parts and 12 fractures in four parts. Seven cases with fracture-dislocation were identified, one head-split fracture, and 14 cases with a metaphyseal head extension of less than 8 mm. After comparing head-shaft displacement, cranialisation of the greater tuberosity as well as head-shaft alignment in the preoperative and postoperative radiographs, overall anatomical or near-anatomical fracture reduction was achieved in 27 of the patients. Only two cases presented postoperative complications. The two cases were complicated with nonunion without screw perforation requiring surgical intervention by re-osteosynthesis. The clinical outcome assessed by the OSS showed an average of 45/48. The age of the group with anatomical or near anatomical reduction and the group with at least one parameter of malreduction was significantly different, 65 and 74 years respectively (p<0.05). No significant differences were found when comparing the sex, surgical time, time to operation or the number of fracture parts. CONCLUSION: The technique described provides a surgical treatment option with lower complication rates and a quality of reduction consistent with the current literature as well as a satisfactory clinical outcome.


Assuntos
Fraturas Cominutivas , Fraturas do Úmero , Fraturas do Ombro , Idoso , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Resultado do Tratamento
4.
Spine (Phila Pa 1976) ; 46(8): 530-537, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33273435

RESUMO

STUDY DESIGN: A retrospective analysis of a single-center consecutive series of patients. OBJECTIVE: To test the hypothesis that using a mobile intraoperative computed tomography in combination with spinal navigation would result in better accuracy of lateral mass and pedicle screws between C3 and T5 levels, compared to cone-beam computed tomography and traditional 2D fluoroscopy. SUMMARY OF BACKGROUND DATA: Use of spinal navigation associated with 3D imaging has been shown to improve accuracy of screw positioning in the cervico-thoracic region. However, use of iCT imaging compared to a cone-beam CT has not been fully investigated in these types of surgical interventions. METHODS: We retrospectively analyzed a series of patients who underwent posterior cervico-thoracic fixations using different intraoperative imaging systems in a single hospital. We identified three different groups of patients: Group A, operated under 2D-fluoroscopic guidance without navigation; Group B: O-arm guidance with navigation; Group C: iCT AIRO guidance with navigation. Primary outcome was the rate of accurately placed screws, measured on intra or postoperative CT scan with Neo et al. classification for cervical pedicles screws and Gertzbein et al. for thoracic pedicle screws. Screws in cervical lateral masses were evaluated according to a new classification created by the authors. RESULTS: Data on 67 patients and 495 screws were available. Overall screw accuracy was 92.8% (95.6% for lateral mass screws, 81.6% for cervical pedicle screws, and 90% for thoracic pedicle screws). Patients operated with iCT AIRO navigation had significantly fewer misplaced screws (2.4%) compared to 2D-fluoroscopic guidance (9.1%) and O-arm navigation (9.7%) (P = 0.0152). Accuracy rate of iCT navigation versus O-arm navigation was significantly higher (P = 0.0042), and there was no statistically significant difference in surgical time between the three Groups (P = 0.5390). CONCLUSION: Use of high-quality CT associated with spinal navigation significantly improved accuracy of screw positioning in the cervico-thoracic region.Level of Evidence: 3.


Assuntos
Vértebras Cervicais/cirurgia , Monitorização Intraoperatória/normas , Neuronavegação/normas , Parafusos Pediculares , Vértebras Torácicas/cirurgia , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Feminino , Fluoroscopia/métodos , Fluoroscopia/normas , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Neuronavegação/métodos , Estudos Retrospectivos , Fusão Vertebral/métodos , Fusão Vertebral/normas , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/normas , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
5.
Orthop Traumatol Surg Res ; 104(7): 1063-1067, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30081217

RESUMO

INTRODUCTION: Posterior pelvic ring fractures frequently pose a problem of stability with an elevated risk of complications. The traditional method of percutaneous sacroiliac (SI) stabilization with the use of fluoroscopic image amplifiers demands a high degree of experience and has an elevated risk of screws' malpositioning. HYPOTHESIS: Intraoperative 3D-CT scan coupled with a navigation system (O-Arm©) can allow screw fixation accuracy while limiting the risk of complications for the treatment of posterior pelvic ring fractures. MATERIAL AND METHODS: Patients with posterior pelvic ring fractures stabilized with percutaneous SI screws through O-Arm© navigation from August 2008 to December 2017 were analyzed. A modified Gras classification was used to determine screws' positioning under CT visualization, and intraoperative and early postoperative complications were documented. RESULTS: Among the 21 patients evaluated, 14 men and 7 women with a mean age of 57.8 years (range 25-91), receiving 39 screws, the rate of misplacement was low: 82% grade I, 15.4% grade II, and only 2.6% grade III. Only one patient underwent revision surgery, not because of misplacement but rather for a secondary implant loosening. No complications occurred in this series. DISCUSSION: This study documented a large series of patients treated for pelvic ring fractures using the intraoperative 3D-CT O-Arm© guided navigation. This surgical approach provided a precise and safe SI screw positioning with no complications. LEVEL OF EVIDENCE: IV, Retrospective study.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Pélvicos/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Ílio/cirurgia , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/lesões , Reoperação , Estudos Retrospectivos , Sacro/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...